Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(8)2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38676045

RESUMO

Among other methods, UWB-based multi-anchor localization systems have been established for industrial indoor localization systems. However, multi-anchor systems have high costs and installation effort. By exploiting the multipath propagation of the UWB signal, the infrastructure and thus the costs of conventional systems can be reduced. Our UWB Single-Anchor Localization System (SALOS) successfully pursues this approach. The idea is to create a localization system with sophisticated signal modeling. Therefore, measured reference, like fingerprinting or training, is not required for position estimation. Although SALOS has already been implemented and tested successfully in an outdoor scenario with multipath propagation, it has not yet been evaluated in an indoor environment with challenging and hardly predictable multipath propagation. For this purpose, we have developed new algorithms for the existing hardware, mainly a three-dimensional statistical multipath propagation model for arbitrary spatial geometries. The signal propagation between the anchor and predefined candidate points for the tag position is modeled in path length and complex-valued receive amplitudes. For position estimation, these modeled signals are combined to multiple sets and compared to UWB measurements via a similarity metric. Finally, a majority decision of multiple position estimates is performed. For evaluation, we implement our localization system in a modular fashion and install the system in a building. For a fixed grid of 20 positions, the localization is evaluated in terms of position accuracy. The system results in correct position estimations for more than 73% of the measurements.

2.
Sensors (Basel) ; 23(4)2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36850796

RESUMO

Device-free localization (DFL) systems exploit changes in the radio frequency channel by measuring, for example, the channel impulse response (CIR), to detect and localize obstacles within a target area. However, due to a lack of well-defined interfaces, missing modularization, as well as complex system configuration, it is difficult to deploy DFL systems outside of laboratory setups. This paper focused on the system view and the challenges that come with setting up a DFL system in an indoor environment. We propose MA-RTI, a modular DFL system that is easy to set up, and which utilizes a multipath-assisted (MA) radio-tomographic imaging (RTI) algorithm. To achieve a modular DFL system, we proposed and implemented an architectural model for DFL systems. For minimizing the configuration overhead, we applied a 3D spatial model, that helps in placing the sensors and calculating the required calibration parameters. Therefore, we configured the system solely with idle measurements and a 3D spatial model. We deployed such a DFL system and evaluated it in a real-world office environment with four sensor nodes. The radio technology was ultra-wideband (UWB) and the corresponding signal measurements were CIRs. The DFL system operated with CIRs that provided a sub-nanosecond time-domain resolution. After pre-processing, the update rate was approximately 46 Hz and it provided a localization accuracy of 1.0 m in 50% of all cases and 1.8 m in 80% of all cases. MA fingerprinting approaches lead to higher localization accuracy, but require a labor-intensive training phase.

3.
Sensors (Basel) ; 22(16)2022 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-36016015

RESUMO

In radio-frequency (RF)-based device-free localization (DFL), the number of sensors acting as RF transmitters and receivers is crucial for accuracy and system costs. Two promising approaches for DFL have been identified in the past: radio tomographic imaging (RTI) and multi-static radar (MSR). RTI in its basic version requires many sensors for high accuracy, which increases the cost. In this paper, we show how RTI benefits from multipath propagation. By evaluating the direct and echo paths, we increase the coverage of the target area, and by utilizing UWB signals, the RTI system is less susceptible to multipath propagation. MSR maps reflections that occur within the target area to reflectors such as persons or other objects. MSR does not require that the person is located near a signal path. Both suggested methods exploit ultra-wideband (UWB) channel impulse response (CIR) measurements. CIR measurements and the modeling of multipath effects either increase the accuracy or reduce the required number of sensors for localization with RTI. We created a test setup and measure UWB CIRs at different positions with a commercially available off-the-shelf UWB radio chip, the Decawave DW1000. We compare the localization results of RTI, multipath-assisted (MA)-RTI, and MSR and investigate a combined approach. We show that RTI is improved by the analysis of multipath propagation; furthermore, MA-RTI results in a better performance compared to MSR: with 50% of all cases, the localization error is better than 0.82 m and in 80% of all cases 1.34 m. The combined approach results in the best localization result with 0.64 m in 50% of all cases.


Assuntos
Radar , Ondas de Rádio , Humanos
4.
Sensors (Basel) ; 20(24)2020 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-33322078

RESUMO

In this paper, we propose a multipath-assisted device-free localization (DFL) system that includes magnitude and phase information (MAMPI). The DFL system employs ultra-wideband (UWB) channel impulse response (CIR) measurements, enabling the extraction of several multipath components (MPCs) and thereby benefits from multipath propagation. We propose a radio propagation model that calculates the effect on the received signal based on the position of a person within a target area. Additionally, we propose a validated error model for the measurements and explain the creation of different feature vectors and extraction of the MPCs from Decawave DW1000 CIR measurements. We evaluate the system via simulations of the position error probability and a measurement setup in an indoor scenario. We compare the performance of MAMPI to a conventional DFL system based on four sensor nodes that measures radio signal strength values. The combination of the magnitude and phase differences for the feature vectors results in a position error probability that is comparable to a conventional system but requires only two sensor nodes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...